Write Your Own Plans#

This page shows you two ways to add your own measurement plans: ask the agent to write one during a session, or install a plan library that belongs to your facility.

OSPREY ships three deliberately generic plans:

  • an n-dimensional grid scan;

  • an orbit response matrix sweep;

  • a closed orbit bump sweep.

You ask for the orbit bump in orbit space rather than in corrector currents. Name the three or four correctors allowed to act, the BPMs where the beam should move and by how much, and the BPMs where it must not move at all. The plan finds the kicks that do it, with no lattice model needed. It walks the bump up and back down step by step across the profile, and verifies each step against the tolerance you asked for. A tolerance narrower than the BPMs’ own noise is refused before anything moves.

Who is trusted, in one paragraph#

Plans are trusted by where they come from:

  • Plans shipped with OSPREY, with a preset, or installed by your facility run as they are.

  • A plan the agent writes mid-conversation is a session plan. It runs only after passing validation, and only as the exact version that passed. Change one character and it must pass again.

You don’t have to remember this rule. The queue enforces it and refuses anything unvalidated, with a message that says what to do.

Two ways to add a plan#

Describe the measurement and let the agent write the plan. It has a bundled skill (writing-bluesky-plans) for exactly this:

Write me a plan that ramps one corrector while logging every
BPM, and holds each setpoint for a settling time I can choose.

The agent writes the plan file, runs it through the validator, and tells you the result. From there it is a normal plan. It appears in BLUESKY’s Plans view, you review its parameters, and it queues and runs like any other. Its session-tier badge stays visible, so a reviewer always knows what they are looking at.

Session plans are working drafts, not durable installations. They live with the running deployment. After a restart of the bridge, they must be validated again before they can run. Move a plan you want to keep into your facility’s library.

  1. Put your plan files in a directory, for example plans/.

  2. Name the directory in your build profile:

    bluesky:
      plan_dir: plans/
    
  3. Run osprey build.

  4. Restart the stack (osprey up). The next osprey up mounts every plan in the directory read-only into the plan stack.

  5. Open BLUESKY’s Plans view and check that your plans are listed next to the shipped plans.

Facility plans are trusted at facility tier. They need no per-session validation, and they are available in every deployment built from the profile. They are listed in BLUESKY’s Plans view and the agent’s catalog like the shipped plans.

To remove a plan from the catalog, shipped or otherwise, list it under excluded_plans in the same block. The plan becomes invisible and non-runnable everywhere.

Anatomy of a plan file

A plan file is a small Python module with three parts:

  • Metadata: three things and no more. These are the plan’s name, a human description, and whether it moves anything on the machine.

  • Parameters: a schema describing the knobs (names, types, limits). BLUESKY’s Plans view turns this schema into a form, so a well-described parameter becomes a well-labeled field. Each parameter that holds channel names also says what the plan does with them. See A plan says what it touches below.

  • The plan function: builds the actual Bluesky plan from the parameters and the resolved devices.

A plan file can also have an optional fourth part, the view. The view is a render function that turns the run’s rows into the plan’s own plots. See Give a plan its own view below.

The agent’s writing-bluesky-plans skill carries the full, current template. To see one, ask the agent to write a minimal plan and read the result.

What the validator checks

Validation is static scrutiny first, then a rehearsal:

  1. Static checks: the file may only import what is on the validator’s allowlist. Anything that reaches for the control system directly is rejected. These checks finish before a single line runs.

  2. A dry run: the plan is executed against mock devices in an isolated process, with all control-system access switched off. It has to run to completion there.

A pass is recorded against the exact content of the file, its fingerprint. The fingerprint is what makes the “exact bytes” rule enforceable.

Why an edited plan must pass again

The pass belongs to the fingerprint, not to the filename. Editing the file changes the fingerprint, so the old pass no longer applies. The queue checks the fingerprint both when a plan is added and when the queue starts. There is no window where edited but unvalidated code can reach the machine.

A bridge restart clears the recorded passes too. That is why a session plan that outlived a restart asks to be validated once more. Facility-tier plans carry no fingerprint bookkeeping. Their trust comes from being installed by you.

Declare the devices a plan may drive#

A plan names channels through its parameters, but the deployment decides which devices exist at all. osprey build derives the device set from your facility file. It writes data/bluesky_devices.yml into the build output: a list of every device the queue server may drive or record. The queue server mounts that file unchanged.

# build/data/bluesky_devices.yml
schema: osprey.facility.bluesky_devices/1
settables:
  - name: SR:MAG:HCM:01:CURRENT:SP
    setpoint: SR:MAG:HCM:01:CURRENT:SP
    readback: SR:MAG:HCM:01:CURRENT:RB
    unit: A
    setpoint_unit: A
readables:
  - name: SR:MAG:HCM:01:CURRENT:RB
    pv: SR:MAG:HCM:01:CURRENT:RB
    unit: A
  - name: SR:DIAG:BPM:01:POSITION:X
    pv: SR:DIAG:BPM:01:POSITION:X
    unit: mm

The file has two lists:

  • Settables are devices a plan may drive. There is one per setpoint channel of the facility file. A settable is written to that channel and read back from the channel it is paired with. A setpoint the facility pairs with no readback reads its own setpoint.

  • Readables are recorded and never written. There is one per readback channel.

A device’s name is its address, which is also the column heading in the run’s data.

A device carries the unit its channel states in the facility file. A settable with a separate readback also carries its setpoint’s unit, as setpoint_unit. Every run records them, so get_run_data and the run’s figure state each column’s unit.

Don’t edit this file: the build rewrites it every time. To change the device set, change the channels under data/facility/ and build again.

A plan the agent writes during a session names channels from this same set. list_devices reads it. When the queue worker is running, two checks refuse a device the file does not declare, and both answer unknown_device:

  • validation refuses such a device in the sample arguments;

  • the pre-enqueue check refuses it in a plan’s own arguments.

The channel finder answers for the whole facility. This file answers for the queue worker, and a plan’s channels come from here.

When a plan drives a settable, the move waits for its readback to come within a bound of the demand. The setpoint’s tolerance in the facility file, next to its pair, sets the bound:

Setpoint’s tolerance

The readback must come within

tolerance: {absolute: <x>}

<x> of the demand, in the channel’s unit.

tolerance: {relative: <f>}

<f> times the demand (a fraction of the demand).

None, on a lane that serves the simulator

Its readback’s motion band: |drift.amplitude| + 6 × the noise sigma. A relative sigma is taken at the seed’s nominal.

None, on a live or stand-in lane

The floor.

The floor is bluesky.settle_tolerance (default 1e-9), an absolute difference, and the bound is never tighter. If the readback is not inside its bound after bluesky.settle_timeout_s (default 5.0 seconds), the move fails and the plan aborts. pyAML measurement steps wait for their readbacks by the same rule, without the floor.

The build warns:

  • once per live or stand-in lane, with the count of setpoints that declare no tolerance;

  • once per scenario that moves a readback beyond its setpoint’s tolerance, since that scenario’s moves time out while it is active.

osprey facility validate prints the same warnings.

A device that physically moves needs a tolerance on its setpoint, and a slow device needs settle_timeout_s raised. Running out of budget always fails the plan: neither key can turn an unsettled move into a successful one.

A deployment serving the simulator in process drives no channels over Channel Access. Its queue server comes up able to browse and describe plans, and to run none of them. That is a plain statement about the deployment, not a fault, and the build says so in its output.

Note

The limits database is not the channel list. The limits are the records of data/facility/limits.yaml. osprey build renders them into build/data/channel_limits.json. The connector’s reference monitor and the runtime’s limits check enforce that file on every write.

The limits database gates writes over a subset of the machine, and nothing enumerates the facility from it. A file listing a few hundred writable channels says nothing about the few thousand the facility has. The device set comes from the facility file, which lists every channel and says which way each one points.

Note

Two lanes, one device file. A profile that turns on second_lane runs one plan lane for the live machine and one for the virtual accelerator. Both mount the same device file, because a facility has one namespace, not one per lane. If the file names a channel that one lane does not serve, that channel fails the lane’s pre-run probe, described below.

Deriving for a live lane is deliberate#

The device set is the facility’s namespace, and the live lane mounts it like any other. That is a decision, not an oversight. A device in the worker’s namespace is a name a plan may reference. It is not a write that has happened.

The gates that decide whether a write lands sit on the write path: the connector’s per-write check, and the bridge’s arming and limits. Holding the machine’s own channels out of the namespace would add no gate to them. It would only hide from the agent the channels it is allowed to read. It would also push you back to hand-written device files that nothing keeps in step with the facility.

One more thing stands behind that decision:

A run is refused before it moves anything. A device file names channels, but it cannot promise that the IOC serving them is up. An unreachable channel used to surface mid-plan, as a connection error out of the first read, with setpoints already applied. The worker now asks that question one message earlier. Before the plan is constructed, the worker probes every address the run’s declared devices touch: each setpoint, each readback, each recorded channel. It probes on that lane’s own connector, and refuses the run if any address does not answer.

refusing plan 'bump' before it moves anything — lane bluesky_live (target live):
2 declared channels did not respond within 5 s: SR:MAG:HCM:07:CURRENT:SP, SR:MAG:HCM:07:CURRENT:RB

Nothing has been written when that message arrives, so nothing is half-done. Each address gets five seconds and one retry. A channel that misses the first probe and answers the second runs.

The sweep as a whole is bounded too: 20 seconds for a small plan, up to 90 for one naming thousands of addresses. The message reports addresses the sweep did not reach inside that bound separately from addresses it asked and got no answer from. Both refuse the run, but they are different findings.

The probe runs per run rather than at enqueue time. A queued plan needs channels that are alive when it runs, and the gap between enqueue and run can be an IOC restart.

Listed as settable, refused at write time#

Being a settable says the facility describes the channel as one that is written. It does not say a write to it will be accepted. Two places answer those two questions. A facility whose two answers differ is a normal deployment, not a misconfiguration:

  • The facility’s description (the graph corpus, or the channel-finder database) answers membership: which channels exist. In graph mode it answers direction too, from the binding’s own writesSignal/readsSignal.

  • The limits database answers permission, at the moment a write is attempted. It says what range the value has to be in, and whether a channel it does not list may be written at all (control_system.limits_checking.mode).

So a graph corpus may mark a channel settable that the limits database refuses. A facility maintains its structural description and its enforced write ranges separately, and OSPREY does not reconcile them at build time. The plan may name that device. When the write is attempted, the target refuses it with a message saying so.

The build does not intersect the two lists. It does not drop a channel from the namespace because the limits file omits it, since that would report a smaller machine than the facility has. On a database paradigm, the same limits file supplied the direction in the first place. There the two agree on which channels are settable by construction, and can still disagree about the value.

The queue server’s device set and the channel finder read the same source: the one the paradigm in force selects. Which channels count as scan devices is therefore the same answer as which channels your facility has.

  • In graph mode, that source is the corpus. The device set, the channel finder and the knowledge graph are three views of one description, and they cannot drift apart.

  • On a database paradigm, the graph is generated from the same channel database (Search the Facility Graph). The three agree as long as the corpus is regenerated when the database changes.

A plan says what it touches#

A plan’s parameters name channels, but a list of names on its own does not say whether the plan drives those channels or only records them. Every plan file answers that outright. A parameter holding channel names is marked as one of:

  • movable: the plan drives it to a value;

  • readable: the plan records it without changing it.

The rest of OSPREY works from that one marking. It decides:

  • which mock devices the validator builds for the dry run;

  • which names are checked against your machine before a plan is queued;

  • what the approval prompt shows the person who is about to say yes;

  • which channel the default plot uses for its x axis.

Each of those used to guess from how a parameter was spelled. Now the plan says it once, and everything reads the same answer.

What a plan's parameter marking decides A plan marks each parameter holding channel names as either movable, meaning the plan drives it, or readable, meaning the plan only records it. That single marking is read by four independent consumers: the validator's stand-in devices, the pre-queue channel check, the approval prompt shown to the human, and the default plot's x axis. your plan file says it once, outright parameter marking movable — the plan drives it readable — it only records it the validator which stand-in devices to build for the rehearsal the pre-queue check which names are checked against your machine the approval prompt what the human is told is about to move the default plot which channel becomes the x axis each of these used to guess from how a parameter was spelled — now they all read the same answer

Two consequences you will notice:

  • The names are yours. Call the parameters whatever your facility calls them: correctors, BPMs, setpoints, monitors. The marking carries the meaning, so nothing downstream depends on the spelling.

  • A plan that moves the machine has to show what it moves. If a plan’s metadata says it writes but the plan marks nothing as movable, the catalog refuses the plan when it loads it. The refusal message says exactly that, and the plan never appears.

    Such a plan must also open a run and state how many points that run will take. Live progress counts against that number. A plan built on top of one of Bluesky’s own scans inherits the run and its point count from that scan, so it states neither itself. It still marks its own parameters, because everything else reads those markings.

  • A plan records what it moves. Every reading is taken at some setting of the channel being moved, and only means something next to it. The validator watches the rehearsal. It refuses a plan that moves a channel without ever recording it alongside its readings, because such a run would finish with no record of what each reading was taken at.

Give a plan its own view#

Every run gets a figure in the BLUESKY panel, and by default it is drawn for you. The default view plots every numeric column the run recorded against the channel the plan drives. When a plan drives more than one channel, the default view plots the columns in the order the readings were taken. For a straightforward measurement, the default view is honest and enough.

A plan that measures something the raw columns cannot show can bring its own view instead. The view is a small render function. It receives the run’s rows and its parameters, and returns the plots the plan itself designs. Two shipped plans do this:

  • orm draws a trace per corrector while the sweep runs. Once there is enough data, it draws the fitted response matrix and per-device scores.

  • orbit_bump_sweep draws the orbit shift across the BPMs at each amplitude step, the residual against its tolerance band, and where the correctors sat while it walked. On a run that was given extra monitor channels, it also draws the monitors’ response.

A panel with nothing to draw is left out rather than drawn empty.

The vocabulary is small on purpose. A figure is a list of panels; each panel has a title, axis labels and units, any notes worth printing beside it, and exactly one mark:

Mark

What it draws

Lines

Named series of x/y points — a sweep, a trend, one line per monitor. A reading the run never took stays a gap in the line, never a zero.

Bars

One value per named category — a score or a total per device.

Heatmap

A labelled 2-D grid — for example BPMs against correctors, each cell a fitted slope.

Three rules keep a view honest, and the framework enforces all three:

  • Drawing never disturbs a plan. A view is computed from data already recorded, after the fact. If it fails, the run and its numbers are untouched. The panel shows the default view with a note saying why.

  • Views name no facility. Labels come from the plan’s parameters and the columns the run recorded, so the same plan draws correct device names at any facility that installs it.

  • Only installed plans draw their own view. A plan’s render runs inside the bridge every time a panel refreshes. So it is honored for plans shipped with OSPREY, with a preset, or installed by your facility. It is not honored for session plans the agent writes mid-conversation. A session plan queues, runs and records data exactly as any other, but its runs show the default view. A view is one more reason to move a plan you want to keep into your facility’s library.

Note

Views apply going forward. The plan code that owns the plan’s name now computes the figure. Adding or fixing a render shows up on the next run, with nothing to migrate.

The exception is old data. A run recorded before OSPREY kept track of which plan produced it has nothing to tie it back to plan code. It keeps showing the default view, whatever you add later. Its numbers are all still there; only the plan’s own view is out of reach.

See also

Plans and the Queue

How a queued plan actually runs, and what refusals mean.